Line 20: Line 20:
  Rule1 ON Power1#state=1 DO backlog Delay 50; Power1 0 ENDON
  Rule1 ON Power1#state=1 DO backlog Delay 50; Power1 0 ENDON
  rule1 1
  rule1 1
  Rule3 ON Power2#state=1 DO backlog Delay 50; Power2 0 ENDON
  Rule2 ON Power2#state=1 DO backlog Delay 50; Power2 0 ENDON
rule2 1
Rule3 ON ANALOG#Voltage1>150 DO Power1 0; Power2 0 ENDON
  rule3 1
  rule3 1
Rule2 ON ANALOG#Voltage1>150 DO Power1 0; Power2 0 ENDON
rule2 1
  (100 is too low, limit sometimes trips before motor starts moving, 200 is a lot)
  (100 is too low, limit sometimes trips before motor starts moving, 200 is a lot)


Line 33: Line 33:
  CMD: rule1
  CMD: rule1
  RSL: RESULT = {"Rule1":{"State":"ON","Once":"OFF","StopOnError":"OFF","Length":54,"Free":457,"Rules":"ON Power1#state=1 DO backlog Delay 100; Power1 0 ENDON"}}
  RSL: RESULT = {"Rule1":{"State":"ON","Once":"OFF","StopOnError":"OFF","Length":54,"Free":457,"Rules":"ON Power1#state=1 DO backlog Delay 100; Power1 0 ENDON"}}
  CMD: rule2
  CMD: rule3
  RSL: RESULT = {"Rule2":{"State":"ON","Once":"OFF","StopOnError":"OFF","Length":40,"Free":471,"Rules":"ON ANALOG#Voltage1>100 DO Power1 0 ENDON"}}
  RSL: RESULT = {"Rule3":{"State":"ON","Once":"OFF","StopOnError":"OFF","Length":40,"Free":471,"Rules":"ON ANALOG#Voltage1>100 DO Power1 0 ENDON"}}
  CMD: adcparam
  CMD: adcparam
  RSL: RESULT = {"AdcParam1":[33,0,4095,0,1024]}
  RSL: RESULT = {"AdcParam1":[33,0,4095,0,1024]}

Revision as of 18:48, 4 October 2024

Omnindoor-ESP32-wiring.png
Caption text
Pin thing Mode in Tasmota Configure Unit menu
4 forward Relay 1
32 reverse Relay 2
33 current ADC Voltage 1
Example Example
curl -u "admin:password" http://10.111/cm?cmnd=power1+1

rules so that motor direction gets activated, with a timeout. But if current limit hits, then cancel

Rule1 ON Power1#state=1 DO backlog Delay 50; Power1 0 ENDON
rule1 1
Rule2 ON Power2#state=1 DO backlog Delay 50; Power2 0 ENDON
rule2 1
Rule3 ON ANALOG#Voltage1>150 DO Power1 0; Power2 0 ENDON
rule3 1
(100 is too low, limit sometimes trips before motor starts moving, 200 is a lot)
set the adc range
AdcParam 33, 0, 4095, 0, 1024

in the console (or by curl) you can view the rules and adcparam

CMD: rule1
RSL: RESULT = {"Rule1":{"State":"ON","Once":"OFF","StopOnError":"OFF","Length":54,"Free":457,"Rules":"ON Power1#state=1 DO backlog Delay 100; Power1 0 ENDON"}}
CMD: rule3
RSL: RESULT = {"Rule3":{"State":"ON","Once":"OFF","StopOnError":"OFF","Length":40,"Free":471,"Rules":"ON ANALOG#Voltage1>100 DO Power1 0 ENDON"}}
CMD: adcparam
RSL: RESULT = {"AdcParam1":[33,0,4095,0,1024]}