Line 26: | Line 26: | ||
(100 is too low, limit sometimes trips before motor starts moving, 200 is a lot) | (100 is too low, limit sometimes trips before motor starts moving, 200 is a lot) | ||
set the adc range https://tasmota.github.io/docs/ADC/ (note: mode 6 is ADC Range, but 33 is what the software returns for some reason, so we just set 33) | |||
AdcParam1 33, 0, 4095, 0, 100 | AdcParam1 33, 0, 4095, 0, 100 | ||
Revision as of 12:00, 7 October 2024
Pin | thing | Mode in Tasmota Configure Unit menu |
4 | lock | Relay 1 |
32 | unlock | Relay 2 |
33 | current | ADC Range 1 |
Example | Example |
curl -u "admin:password" http://10.111/cm?cmnd=power1+1
rules so that motor direction gets activated, with a timeout. But if current limit hits, then cancel
Rule1 ON Power1#state=1 DO backlog Delay 50; Power1 0 ENDON rule1 1 Rule2 ON Power2#state=1 DO backlog Delay 50; Power2 0 ENDON rule2 1 Rule3 ON ANALOG#Voltage1>80 DO Power1 0; Power2 0 ENDON rule3 1 (100 is too low, limit sometimes trips before motor starts moving, 200 is a lot)
set the adc range https://tasmota.github.io/docs/ADC/ (note: mode 6 is ADC Range, but 33 is what the software returns for some reason, so we just set 33)
AdcParam1 33, 0, 4095, 0, 100
in the console (or by curl) you can view the rules and adcparam
CMD: rule1 RSL: RESULT = {"Rule1":{"State":"ON","Once":"OFF","StopOnError":"OFF","Length":54,"Free":457,"Rules":"ON Power1#state=1 DO backlog Delay 100; Power1 0 ENDON"}} CMD: rule3 RSL: RESULT = {"Rule3":{"State":"ON","Once":"OFF","StopOnError":"OFF","Length":40,"Free":471,"Rules":"ON ANALOG#Voltage1>80 DO Power1 0 ENDON"}} CMD: adcparam RSL: RESULT = {"AdcParam1":[33,0,4095,0,100]}