{"POWER1":"ON"}0jake@eg:~/sketchbook/omnindoor$ curl -u "admin:password" http://10.111/cm?cmnd=POWER1+off
Header text | Header text | |
---|---|---|
Pin | thing | Mode in Tasmota Configure Unit menu |
4 | forward | Power |
14 | reverse | Power |
33 | current | ADC Current (bottom of list) |
Example | Example | |
Example | Example | |
Example | Example |
{"POWER1":"OFF"}0jake@eg:~/sketchbook/omnindoor$ curl -u "admin:password" http://10.111/cm?cmnd=rule1+1
{"Rule1":{"State":"ON","Once":"OFF","StopOnError":"OFF","Length":0,"Free":511,"Rules":""}}
turn off when limit current hit Rule1 ON Power1#state=1 DO backlog Delay 30; Power1 0 ENDON rule1 1
Rule2 ON ANALOG#Voltage1>100 DO Power1 0 ENDON rule2 1
set the adc range
AdcParam 6, 0, 4095, 0, 1024
in the console you can view the rules:
CMD: rule1
RSL: RESULT = {"Rule1":{"State":"ON","Once":"OFF","StopOnError":"OFF","Length":54,"Free":457,"Rules":"ON Power1#state=1 DO backlog Delay 100; Power1 0 ENDON"}}
CMD: rule2
RSL: RESULT = {"Rule2":{"State":"ON","Once":"OFF","StopOnError":"OFF","Length":40,"Free":471,"Rules":"ON ANALOG#Voltage1>100 DO Power1 0 ENDON"}}