Omnindoor

Revision as of 19:12, 3 October 2024 by Jerkey (talk | contribs)

rules so that motor direction gets activated, with a timeout. But if current limit hits, then cancel

Omnindoor-ESP32-wiring.png
Caption text
Pin thing Mode in Tasmota Configure Unit menu
4 forward Power
14 reverse Power
33 current ADC Current (bottom of list)
Example Example
curl -u "admin:password" http://10.111/cm?cmnd=POWER1+off
curl -u "admin:password" http://10.111/cm?cmnd=rule1+1
Rule1 ON Power1#state=1 DO backlog Delay 30; Power1 0 ENDON
rule1 1
Rule3 ON Power2#state=1 DO backlog Delay 30; Power2 0 ENDON
rule3 1
Rule2 ON ANALOG#Voltage1>100 DO Power1 0; Power2 0 ENDON
rule2 1
set the adc range
AdcParam 6, 0, 4095, 0, 1024

in the console you can view the rules:

CMD: rule1
RSL: RESULT = {"Rule1":{"State":"ON","Once":"OFF","StopOnError":"OFF","Length":54,"Free":457,"Rules":"ON Power1#state=1 DO backlog Delay 100; Power1 0 ENDON"}}
CMD: rule2
RSL: RESULT = {"Rule2":{"State":"ON","Once":"OFF","StopOnError":"OFF","Length":40,"Free":471,"Rules":"ON ANALOG#Voltage1>100 DO Power1 0 ENDON"}}
CMD: adcparam
RSL: RESULT = {"AdcParam1":[33,0,4095,0,1024]}